PageSourceSearch

https://radxtech.com/assets/catalyst-gbe-DmjXaV7C.js

js radxtech.com collected 2026-10-07 10:01:39 UTC 12,444 bytes, 7 lines download raw bytes

1import{j as e}from"./query-cHJHLq2Q.js";import{u as o,H as d,F as c}from"./index-DuDYZYaR.js";import"./react-vendor-DrsKylZW.js";import"./radix-ui-UNqLbP3Q.js";const a="#146499",n="#1A2744";function s({label:l,value:t}){return e.jsxs("tr",{className:"border-b border-gray-200",children:[e.jsx("td",{className:"py-2 pr-4 text-xs font-semibold text-gray-600 w-[42%] align-top",children:l}),e.jsx("td",{className:"py-2 text-xs text-gray-900 align-top",children:t})]})}function r({children:l}){return e.jsxs("div",{className:"flex items-center gap-2 mb-3 mt-6",children:[e.jsx("div",{className:"w-1 h-5 rounded-full flex-shrink-0",style:{background:a}}),e.jsx("h3",{className:"text-xs font-bold uppercase tracking-widest",style:{color:a},children:e.jsx(c,{devId:"b21906",guard:{file:"src/pages/datasheet/catalyst-gbe.tsx",tagName:"h3",sourceKind:"bound-expression",contentKey:null,contentKeyTemplate:null,expressionHash:"sha256:10910087de24bfcabe854fda62b5023a61fe531705043b9979fdf00f12c4c0ec"},children:l})})]})}const x=[{pn:"PXIe-GbE-2x25GbE-CX6",nic:"NVIDIA® Mellanox® MCX631102AN-ADAT",ports:"2 × SFP28 (25 GbE)",hostIf:"PCIe Gen 4 ×8",wSlot:"~13 W",msrp:"$3,999"},{pn:"PXIe-GbE-4x10GbE-XL710",nic:"Intel® XL710-BM1",ports:"4 × SFP+ (10 GbE)",hostIf:"PCIe Gen 4 ×8",wSlot:"~10 W",msrp:"$4,999"},{pn:"PXIe-GbE-2x100GbE-CX6",nic:"NVIDIA® Mellanox® MCX623106AN-CDAT",ports:"2 × QSFP56 (100 GbE)",hostIf:"PCIe Gen 4 ×8",wSlot:"~27 W",msrp:"$5,999"}];function g(){const l=o();return e.jsxs(e.Fragment,{children:[e.jsxs(d,{children:[e.jsx("title",{children:"Catalyst PXIe-GbE Preliminary Datasheet — RADX Technologies"}),e.jsx("meta",{name:"description",content:"Preliminary datasheet for the RADX Catalyst PXIe-GbE 4×10 / 2×25 / 2×100 GbE NIC modules."}),e.jsx("meta",{name:"robots",content:"noindex"}),e.jsx("style",{children:`
2          @media print {
3            .no-print { display: none !important; }
4            body { -webkit-print-color-adjust: exact; print-color-adjust: exact; }
5            @page { margin: 0.5in; size: letter; }
6          }
7        `})]}),e.jsxs("div",{className:"no-print sticky top-[108px] z-40 flex items-center justify-between px-6 py-2.5 bg-gray-100 border-b border-gray-200 shadow-sm",children:[e.jsxs("button",{onClick:()=>l("/products/catalyst-gbe"),className:"flex items-center gap-2 text-sm font-medium text-gray-600 hover:text-gray-900 transition-colors",children:[e.jsx("svg",{className:"w-4 h-4",fill:"none",stroke:"currentColor",viewBox:"0 0 24 24",children:e.jsx("path",{strokeLinecap:"round",strokeLinejoin:"round",strokeWidth:2,d:"M15 19l-7-7 7-7"})}),"Back to Product Page"]}),e.jsxs("div",{className:"flex items-center gap-3",children:[e.jsx("span",{className:"text-xs text-gray-400 font-medium uppercase tracking-wider",children:"Preliminary Datasheet"}),e.jsxs("a",{href:"/data/RADX_Catalyst_PXIe-GbE_Datasheet.pdf",download:!0,className:"flex items-center gap-2 px-4 py-2 rounded-lg text-sm font-semibold text-white transition-colors",style:{background:a},children:[e.jsx("svg",{className:"w-4 h-4",fill:"none",stroke:"currentColor",viewBox:"0 0 24 24",children:e.jsx("path",{strokeLinecap:"round",strokeLinejoin:"round",strokeWidth:2,d:"M4 16v1a3 3 0 003 3h10a3 3 0 003-3v-1m-4-4l-4 4m0 0l-4-4m4 4V4"})}),"Download PDF"]})]})]}),e.jsx("div",{className:"bg-white min-h-screen",children:e.jsxs("div",{className:"max-w-[850px] mx-auto px-8 py-10",children:[e.jsxs("div",{className:"flex items-start justify-between mb-6 pb-5 border-b-2",style:{borderColor:a},children:[e.jsxs("div",{className:"flex-1",children:[e.jsxs("div",{className:"flex items-center gap-3 mb-2",children:[e.jsx("img",{src:"/assets/RADX_logo_2color_transparent_background.png",alt:"RADX Technologies",className:"h-8 w-auto"}),e.jsx("span",{className:"text-xs font-bold uppercase tracking-widest text-gray-400",children:"|  Preliminary Datasheet"})]}),e.jsx("h1",{className:"text-2xl font-bold leading-tight mt-3",style:{color:n},children:"Catalyst PXIe-GbE"}),e.jsx("p",{className:"text-sm font-semibold mt-0.5",style:{color:a},children:"COTS Single-Slot PXIe/CPCIe High-Performance Ethernet NIC Modules"}),e.jsx("p",{className:"text-xs text-gray-500 mt-1",children:"4×10 GbE / 2×25 GbE / 2×100 GbE Configurations  |  From $3,999 H126 MSRP  |  BAA / TAA Compliant"})]}),e.jsx("div",{className:"ml-6 flex-shrink-0",children:e.jsx("img",{src:"/assets/Catalyst GbE Products.png",alt:"RADX Catalyst PXIe-GbE Modules",className:"w-[210px] h-auto rounded-xl border border-gray-200 shadow-lg bg-white p-2 object-contain"})})]}),e.jsxs("p",{className:"text-sm text-gray-700 leading-relaxed mb-2",children:["The ",e.jsx("strong",{children:"RADX Catalyst PXIe-GbE"})," family are COTS, single-slot PXIe/CPCIe HPC Ethernet NIC modules available in 4×10 GbE, 2×25 GbE, and 2×100 GbE configurations. Based on the RADX patent-pending ",e.jsx("strong",{children:"Catalyst-X™"})," carrier card design with PCIe Gen 4 ×8 support, Catalyst-GbE integrates NVIDIA® Mellanox® ConnectX-6 and Intel® XL710-BM1 PCIe NICs with support for RDMA (iWARP, RoCEv2), GPUDirect, IEEE-1588v2 Precision Time Protocol (PTP), and IPsec offload — delivering enterprise data center and HPC networking performance directly inside any PXIe chassis."]}),e.jsx(r,{children:"Key Features"}),e.jsx("ul",{className:"grid grid-cols-2 gap-x-6 gap-y-1.5 mb-2",children:["3 configurations: 4×10, 2×25, 2×100 GbE","RADX patent-pending Catalyst-X™ carrier card","PCIe Gen 4 ×8 host interface","RDMA: iWARP & RoCEv2 (CX6 models)","GPUDirect support (CX6 models)","IEEE-1588v2 Precision Time Protocol (PTP)","IPsec offload (CX6 models)","Intel® XL710-BM1 & NVIDIA® Mellanox® CX6","Single-slot PXIe / CPCIe form factor","Standard vendor drivers — no custom RADX drivers","Windows & Linux compatible","BAA & TAA compliant","Designed & assembled 
7in the USA","GSA available via GSAMart by TestMart","Long-life-cycle product","~30-day typical delivery ARO"].map(t=>e.jsxs("li",{className:"flex items-start gap-2 text-xs text-gray-800",children:[e.jsx("span",{className:"w-2 h-2 rounded-full mt-0.5 flex-shrink-0",style:{background:a}}),t]},t))}),e.jsxs("div",{className:"grid grid-cols-2 gap-8 mt-2",children:[e.jsxs("div",{children:[e.jsx(r,{children:"Electrical & Mechanical Specifications"}),e.jsx("table",{className:"w-full",children:e.jsxs("tbody",{children:[e.jsx(s,{label:"Form Factor",value:"Single-slot PXIe / CPCIe"}),e.jsx(s,{label:"Host Interface",value:"PCIe Gen 4 ×8"}),e.jsx(s,{label:"Configurations",value:"4×10 GbE, 2×25 GbE, 2×100 GbE"}),e.jsx(s,{label:"Controllers",value:"Intel® XL710-BM1; NVIDIA® Mellanox® MCX631102AN-ADAT (25G); MCX623106AN-CDAT (100G)"}),e.jsx(s,{label:"Port Types",value:"SFP+ (10G), SFP28 (25G), QSFP56 (100G)"}),e.jsx(s,{label:"RDMA",value:"iWARP, RoCEv2 (CX6 models)"}),e.jsx(s,{label:"GPUDirect",value:"Yes (CX6 models)"}),e.jsx(s,{label:"Time Sync",value:"IEEE-1588v2 PTP (CX6 models)"}),e.jsx(s,{label:"Offload",value:"IPsec (CX6 models)"}),e.jsx(s,{label:"Power / Slot",value:"~10 W (4×10G), ~13 W (2×25G), ~27 W (2×100G)"}),e.jsx(s,{label:"OS Support",value:"Windows 10/11, Linux (standard vendor drivers)"}),e.jsx(s,{label:"Driver Requirement",value:"Standard Intel / NVIDIA Mellanox drivers"})]})}),e.jsx(r,{children:"Compliance & Certifications"}),e.jsx("table",{className:"w-full",children:e.jsxs("tbody",{children:[e.jsx(s,{label:"Buy American Act",value:"BAA Compliant"}),e.jsx(s,{label:"Trade Agreements Act",value:"TAA Compliant"}),e.jsx(s,{label:"Country of Assembly",value:"United States of America"}),e.jsx(s,{label:"GSA Availability",value:"Yes — via GSAMart by TestMart"}),e.jsx(s,{label:"Delivery",value:"~30–45 days ARO (small volumes)"})]})})]}),e.jsxs("div",{children:[e.jsx(r,{children:"Applications"}),e.jsx("ul",{className:"space-y-1.5 mb-2",children:["High-speed data streaming & network traffic generation/analysis","Electronic Warfare (EW) & Signals Intelligence (SIGINT)","Distributed test systems requiring high-throughput inter-chassis communication","Real-time data acquisition & recording over Ethernet","Communications test & protocol analysis","Automated Test Equipment (ATE) with networked DUTs","HPC compute clusters within PXIe chassis","GPUDirect data transfers between NIC and GPU"].map(t=>e.jsxs("li",{className:"flex items-start gap-2 text-xs text-gray-800",children:[e.jsx("span",{className:"w-2 h-2 rounded-full mt-0.5 flex-shrink-0",style:{background:a}}),t]},t))}),e.jsx(r,{children:"Compatible Chassis"}),e.jsx("ul",{className:"space-y-1.5 mb-4",children:["NI PXIe chassis (all standard slots)","Keysight PXIe chassis","Pickering PXIe chassis","All standard PXIe / CPCIe chassis"].map(t=>e.jsxs("li",{className:"flex items-start gap-2 text-xs text-gray-800",children:[e.jsx("span",{className:"w-2 h-2 rounded-full mt-0.5 flex-shrink-0",style:{background:n}}),t]},t))}),e.jsx(r,{children:"Catalyst-X™ Carrier Card"}),e.jsxs("p",{className:"text-xs text-gray-700 leading-relaxed",children:["All Catalyst PXIe-GbE modules are built on the RADX patent-pending ",e.jsx("strong",{children:"Catalyst-X™"})," carrier card — a purpose-designed PXIe/CPCIe single-slot carrier that integrates standard PCIe NIC cards into the PXIe form factor. PCIe Gen 4 ×8 host interface ensures full bandwidth utilization for all three NIC configurations. Standard vendor drivers are used throughout; no custom RADX drivers are required."]})]})]}),e.jsx(r,{children:"Ordering Information — Part Numbers & H126 MSRP"}),e.jsx("div",{className:"rounded-lg border border-gray-200 overflow-hidden shadow-sm",children:e.jsxs("table",{className:"w-full text-xs border-collapse",children:[e.jsxs("thead",{children:[e.jsx("tr",{children:e.jsx("td",{colSpan:6,className:"px-3 py-2 text-center text-white text-xs font-semibold",style:{background:n},children:"RADX Catalyst PXIe-GbE — Part Numbers, Configurations & H126 MSRP"})}),e.jsxs("tr",{style:{background:"#f0f0f0"},children:[e.jsx("th",{className:"border border-gray-200 px-2 py-1.5 text-left font-semibold text-gray-700",children:"Part Number"}),e.jsx("th",{className:"border border-gray-200 px-2 py-1.5 text-left font-semibold text-gray-700",children:"Integrated PCIe NIC"}),e.jsx("th",{className:"border border-gray-200 px-2 py-1.5 text-left font-semibold text-gray-700",children:"Ports"}),e.jsx("th",{className:"border border-gray-200 px-2 py-1.5 text-left font-semibold text-gray-700",children:"Host I/F"}),e.jsx("th",{className:"border border-gray-200 px-2 py-1.5 text-left font-semibold text-gray-700",children:"W / Slot"}),e.jsx("th",{className:"border border-gray-200 px-2 py-1.5 text-left font-semibold text-gray-700",children:"H126 MSRP*"})]})]}),e.jsx("tbody",{children:x.map((t,i)=>e.jsxs("tr",{className:i%2===0?"bg-white":"bg-gray-50",children:[e.jsx("td",{className:"border border-gray-200 px-2 py-1.5 font-mono font-bold",style:{color:a},children:t.pn}),e.jsx("td",{className:"border border-gray-200 px-2 py-1.5 text-gray-800",children:t.nic}),e.jsx("td",{className:"border border-gray-200 px-2 py-1.5 text-gray-800",children:t.ports}),e.jsx("td",{className:"border border-gray-200 px-2 py-1.5 text-gray-800",children:t.hostIf}),e.jsx("td",{className:"border border-gray-200 px-2 py-1.5 text-gray-800",children:t.wSlot}),e.jsx("td",{className:"border border-gray-200 px-2 py-1.5 font-bold",style:{color:a},children:t.msrp})]},t.pn))})]})}),e.jsx("p",{className:"text-[10px] text-gray-400 mt-1.5",children:"*FOB San Jose. Excludes US import tariffs not in effect prior to RADX PO acceptance. Contact RADX for current availability and lead times."}),e.jsxs("div",{className:"mt-10 pt-5 border-t border-gray-200 flex items-center justify-between",children:[e.jsxs("div",{children:[e.jsx("p",{className:"text-[10px] text-gray-400 leading-relaxed",children:"RADX Technologies, Inc.  |  San Jose, CA  |  [email protected]  |  +1 (619) 677-1849 x1"}),e.jsxs("p",{className:"text-[10px] text-gray-400",children:["© ",new Date().getFullYear()," RADX Technologies, Inc. All rights reserved. Specifications subject to change without notice."]})]}),e.jsxs("div",{className:"text-right",children:[e.jsx("p",{className:"text-[10px] font-bold uppercase tracking-widest",style:{color:a},children:"Preliminary"}),e.jsxs("p",{className:"text-[10px] text-gray-400",children:["Rev 0.1 — ",new Date().toLocaleDateString("en-US",{month:"long",year:"numeric"})]})]})]})]})})]})}export{g as default};

Line numbers count LF bytes from the start of the resource, as the search results do. Vendor segments are library code the classifier recognised; they are stored but not indexed. Bytes are shown as Latin1 characters, one per byte.