PageSourceSearch

https://iet-inc.net/assets/CaseStudyClinton-CUnrdoy6.js

js iet-inc.net collected 2026-10-07 15:50:01 UTC 8,806 bytes, 1 lines download raw bytes

1import{j as e,S as i,L as n,i as r,B as o,v as s,m as l,l as d,I as c,f as t}from"./index-DFmzKkTp.js";import{P as m}from"./ProjectDataSection-B2mJPHc7.js";function g(){const a={year:"2015",duration:"4 months",contaminants:["BTEX","Petroleum Hydrocarbons"],technologies:["In-Situ Chemical Oxidation (ISCO)","Direct Push Injection","Advanced Oxidation Reagents"],keyResults:["Over 95% BTEX reduction achieved","TPH concentrations below regulatory standards","Site approved for regulatory closure","Rapid treatment timeline minimized costs"]};return e.jsxs("div",{className:"min-h-screen bg-gray-950 text-white py-20",children:[e.jsx(i,{title:"Clinton NY Former Gas Station Petroleum Remediation Case Study | IET",description:"IET remediated a former gas station in Clinton, New York — petroleum hydrocarbon and BTEX treatment using in-situ remediation technologies.",keywords:"Clinton NY, gas station remediation, petroleum hydrocarbons, BTEX, New York remediation",canonical:"/CaseStudyClinton"}),e.jsxs("div",{className:"max-w-4xl mx-auto px-4 sm:px-6 lg:px-8",children:[e.jsx(n,{to:r("CaseStudies"),children:e.jsxs(o,{className:"mb-6 bg-gradient-to-r from-green-600 to-blue-600 text-white hover:from-green-700 hover:to-blue-700",children:[e.jsx(s,{className:"mr-2 w-4 h-4"}),"Back to Case Studies"]})}),e.jsxs(l.div,{initial:{opacity:0,y:20},animate:{opacity:1,y:0},transition:{duration:.6},children:[e.jsx("h1",{className:"text-4xl md:text-5xl font-bold mb-4 bg-gradient-to-r from-green-400 via-emerald-500 to-green-600 bg-clip-text text-transparent",children:"Clinton Former Gas Station"}),e.jsx("div",{className:"flex flex-wrap gap-4 mb-6 text-gray-400",children:e.jsxs("div",{className:"flex items-center gap-2",children:[e.jsx(d,{className:"w-4 h-4"}),e.jsx("span",{children:"Clinton, New York"})]})}),e.jsx("img",{src:"https://images.unsplash.com/photo-1545259741-2ea3ebf61fa3?w=800&auto=format&fit=crop",alt:"IET in-situ chemical oxidation petroleum remediation at former gas station in Clinton NY treating BTEX and petroleum hydrocarbon contamination in soil and groundwater",className:"w-full h-96 object-cover rounded-xl mb-8"}),e.jsxs("div",{className:"space-y-8",children:[e.jsx(m,{projectData:a}),e.jsxs("div",{children:[e.jsxs("h3",{className:"text-2xl font-bold mb-4 flex items-center gap-2",children:[e.jsx(c,{className:"w-6 h-6 text-green-500"}),"Target Contaminants"]}),e.jsxs("div",{className:"flex flex-wrap gap-2",children:[e.jsx(t,{className:"bg-orange-500/10 text-orange-400 border border-orange-500/20",children:"BTEX"}),e.jsx(t,{className:"bg-orange-500/10 text-orange-400 border border-orange-500/20",children:"Petroleum Hydrocarbons"})]})]}),e.jsxs("div",{children:[e.jsx("h3",{className:"text-2xl font-bold mb-4",children:"Site Background"}),e.jsx("p",{className:"text-gray-300 leading-relaxed mb-4",children:"The site is a former gas station located in Clinton, New York. Historical operations at the facility resulted in releases of petroleum products, leading to soil and groundwater contamination with benzene, toluene, ethylbenzene, and xylene (BTEX) compounds, as well as total petroleum hydrocarbons (TPH)."}),e.jsx("p",{className:"text-gray-300 leading-relaxed",children:"The contamination posed risks to nearby receptors and required an effective remediation approach to achieve regulatory closure."})]}),e.jsxs("div",{children:[e.jsx("h3",{className:"text-2xl font-bold mb-4",children:"Remediation Strategy"}),e.jsx("p",{className:"text-gray-300 leading-relaxed mb-4",children:"IET implemented an in-situ chemical oxidation (ISCO) program designed to rapidly destroy petroleum hydrocarbons in both soil and groundwater. The treatment approach utilized:"}),e.jsxs("ul",{className:"list-disc list-inside text-gray-300 space-y-2 mb-4 ml-4",children:[e.jsx("li",{children:"Advanced oxidation reagents for rapid contaminant destruction"}),e.jsx("li",{children:"Strategic injection point placement to maximize treatment zone coverage"}),e.jsx("li",{children:"Multiple treatment phases to address residual contamination"})]})]}),e.jsxs("div",{children:[e.jsx("h3",{className:"text-2xl font-bold mb-4",children:"Implementation"}),e.jsx("p",{className:"text-gray-300 leading-relaxed mb-4",children:"The injection program was executed using direct-push technology to deliver oxidation reagents throughout the contaminated zone. IET's experienced field crew completed the work efficie
1ntly while maintaining strict safety protocols."}),e.jsx("p",{className:"text-gray-300 leading-relaxed",children:"Treatment depths extended through the contaminated soil and into the groundwater zone to ensure comprehensive remediation."})]}),e.jsxs("div",{children:[e.jsx("h3",{className:"text-2xl font-bold mb-4",children:"Results"}),e.jsx("p",{className:"text-gray-300 leading-relaxed mb-4",children:"The chemical oxidation treatment achieved significant reductions in petroleum contamination:"}),e.jsxs("ul",{className:"list-disc list-inside text-gray-300 space-y-2 mb-4 ml-4",children:[e.jsx("li",{children:"BTEX compounds reduced by over 95%"}),e.jsx("li",{children:"TPH concentrations decreased below regulatory standards"}),e.jsx("li",{children:"Rapid treatment timeline minimized project costs"}),e.jsx("li",{children:"Site approved for regulatory closure"})]})]}),e.jsxs("div",{className:"bg-gray-900/50 border border-gray-700 rounded-lg p-6 mb-6",children:[e.jsx("h3",{className:"text-2xl font-bold text-white mb-4",children:"Technical Approach & Petroleum ISCO Delivery"}),e.jsx("p",{className:"text-gray-300 leading-relaxed mb-4",children:"This former gas station in Clinton, New York required in-situ chemical oxidation (ISCO) to address BTEX and TPH contamination from historical petroleum releases. IET's ISCO program utilized advanced oxidation reagents delivered via direct-push injection technology — a method that advances injection rods to the target depth without drilling fluid, enabling rapid, cost-effective reagent placement throughout the contaminated soil and groundwater zone."}),e.jsx("p",{className:"text-gray-300 leading-relaxed mb-4",children:"Strategic injection point placement maximized treatment zone coverage by spacing injection points to achieve overlapping radii of influence (ROI), ensuring that the oxidant contacted all contaminated subsurface volumes. Multiple treatment phases addressed residual contamination — petroleum sites commonly have NAPL mass that slowly desorbs from soil into groundwater, requiring phased oxidant delivery to destroy re-dissolving contaminants as they enter the dissolved phase."}),e.jsx("p",{className:"text-gray-300 leading-relaxed",children:"The treatment extended through the contaminated soil into the groundwater zone, addressing both the vadose zone source mass and the dissolved-phase plume. The 95%+ BTEX reduction and TPH reduction below regulatory standards enabled rapid site closure — demonstrating the effectiveness of ISCO for former gas station sites where regulatory closure and property reuse are the primary objectives. The rapid treatment timeline minimized total project costs compared to long-term pump-and-treat or monitored natural attenuation approaches."})]}),e.jsxs("div",{className:"bg-gray-900/50 border border-gray-700 rounded-lg p-6 mb-6",children:[e.jsx("h3",{className:"text-2xl font-bold text-white mb-4",children:"Clinton Site Context & Central New York Geology"}),e.jsx("p",{className:"text-gray-300 leading-relaxed mb-4",children:"Clinton, New York is located in Oneida County within the Erie-Ontario Lowland physiographic province. The shallow geology consists of Quaternary-age glacial till and lacustrine deposits overlying Devonian and Silurian-age sedimentary bedrock — predominantly shale, limestone, and sandstone. The glacial deposits create moderate-permeability conditions with a shallow water table, suitable for direct-push ISCO delivery."}),e.jsx("p",{className:"text-gray-300 leading-relaxed",children:"Former gas station sites in central New York commonly have petroleum contamination from UST systems that leaked over decades of operation. The BTEX and TPH contamination at this site posed risks to nearby receptors, requiring effective remediation to achieve regulatory closure. IET's ISCO approach — with its ability to destroy petroleum contaminants in place without excavation — is ideal for these sites, as it enables regulatory closure and property reuse without the disruption and expense of soil removal and disposal."})]}),e.jsxs("div",{className:"bg-gray-800/50 border border-gray-700 rounded-lg p-6",children:[e.jsx("h4",{className:"text-lg font-semibold mb-3",children:"Project Category"}),e.jsx(t,{className:"bg-blue-500/10 text-blue-400 border border-blue-500/20",children:"Petroleum Contamination"})]})]})]})]})]})}export{g as default};

Line numbers count LF bytes from the start of the resource, as the search results do. Vendor segments are library code the classifier recognised; they are stored but not indexed. Bytes are shown as Latin1 characters, one per byte.