1(function(){try{var e=typeof window<"u"?window:typeof global<"u"?global:typeof globalThis<"u"?globalThis:typeof self<"u"?self:{};e.SENTRY_RELEASE={id:"95830b11ff50f9e7292c5691d851aab9e169cfb2"};var t=new e.Error().stack;t&&(e._sentryDebugIds=e._sentryDebugIds||{},e._sentryDebugIds[t]="e345f62d-bdf1-4d76-895f-86cad0f6c804",e._sentryDebugIdIdentifier="sentry-dbid-e345f62d-bdf1-4d76-895f-86cad0f6c804")}catch{}})();const l={typeCode:"HV-03",country:"GB",title:"Local Exhaust Ventilation (LEV) Test Certificate",version:6,defaultValidityMonths:14,issueDateField:"examinationDate",propertySource:{address:"premisesAddress"},steps:[{key:"premises",label:"Premises",title:"Certificate & Premises Details",content:[{kind:"section",key:"certDetails",columns:2,fields:[{key:"certRef",type:"text",label:"Certificate Reference",validation:{required:!0},placeholder:"e.g. LEV-2025-001"},{key:"examinationDate",type:"date",label:"Examination Date",validation:{required:!0},defaultValue:"today"},{key:"nextExaminationDue",type:"date",defaultValue:"expiry",label:"Next Examination Due",validation:{required:!0},helpText:"Maximum 14 months from examination date. COSHH Schedule 4 sets shorter maxima: 1 month for blasting of metal castings and jute cloth manufacture, 6 months for grinding or polishing metal articles and non-ferrous metal castings."}]},{kind:"section",key:"premisesDetails",title:"Premises",columns:2,fields:[{key:"businessName",prefillFrom:"companyName",type:"text",label:"Business Name",validation:{required:!0}},{key:"departmentArea",type:"text",label:"Department / Area",helpText:"Specific department, workshop or area where LEV is located"},{key:"premisesAddress",type:"textarea",label:"Premises Address",validation:{required:!0},colSpan:2}]},{kind:"section",key:"responsiblePerson",title:"Responsible Person",columns:2,fields:[{key:"responsiblePersonName",type:"text",label:"Name",validation:{required:!0}},{key:"responsiblePersonPosition",type:"text",label:"Position",validation:{required:!0}}]}]},{key:"examiner",label:"Examiner",title:"Examiner Details",content:[{kind:"section",key:"examinerDetails",columns:2,fields:[{key:"examinerName",type:"text",label:"Examiner Name",validation:{required:!0}},{key:"examinerCompany",prefillFrom:"companyName",type:"text",label:"Company",validation:{required:!0}},{key:"examinerQualifications",type:"text",label:"Qualifications / Competence",validation:{required:!0},colSpan:2,helpText:"e.g. BOHS P601, P602, COSHH competent person"}]},{kind:"section",key:"testEquipment",title:"Test Equipment",columns:2,fields:[{key:"instrumentMake",prefillFrom:"instrumentMakeModel",type:"text",label:"Instrument Make / Model",validation:{required:!0}},{key:"instrumentSerial",prefillFrom:"instrumentSerial",type:"text",label:"Serial Number",validation:{required:!0}},{key:"instrumentCalibrationDate",prefillFrom:"instrumentCalibrationDate",type:"date",label:"Calibration Date",validation:{required:!0},helpText:"Instrument must be in calibration at time of examination"}]}]},{key:"system",label:"System",title:"LEV System Details",content:[{kind:"section",key:"systemIdentification",columns:2,fields:[{key:"systemRef",type:"text",label:"System Reference / ID",validation:{required:!0},helpText:"Unique identifier for this LEV system"},{key:"systemManufacturer",type:"text",label:"Manufacturer"},{key:"processControlled",type:"text",label:"Process Controlled",validation:{required:!0},helpText:"e.g. welding, woodworking, paint spraying, grinding"},{key:"substancesControlled",type:"text",label:"Substances Controlled",validation:{required:!0},helpText:"e.g. wood dust, welding fume, paint mist, silica dust"},{key:"systemType",type:"select",label:"System Type",validation:{required:!0},options:[{value:"extraction_hood",label:"Extraction Hood"},{value:"booth",label:"Booth"},{value:"enclosure",label:"Enclosure (Total or Partial)"},{value:"on_tool",label:"On-Tool Extraction"},{value:"slot_hood",label:"Slot Hood"},{value:"canopy_hood",label:"Canopy Hood"},{value:"downdraught",label:"Downdraught Bench"},{value:"other",label:"Other"}]},{key:"systemTypeOther",type:"text",label:"Other System Type",visibleWhen:{field:"systemType",op:"eq",value:"other"}},{key:"dateInstalled",type:"date",label:"Date Installed",helpText:"Approximate date if exact date unknown"},{key:"numberOfHoods",type:"number",label:"Number of Hoods / Capture Points",validation:{min:1,max:50}}]}]},{key:"hood",label:"Hood",title:"Hood / Enclosure Assessment",content:[{kind:"section",key:"hoodAssessment",columns:2,fields:[{key:"hoodType",type:"text",label:"Hood / Enclosure Type",validation:{required:!0},helpText:"e.g. capturing hood, receiving hood, partial enclosure"},{key:"hoodDimensions",type:"text",label:"Dimensions (L x W x H)",helpText:"In millimetres",suffix:"mm"},{key:"hoodCondition",type:"select",label:"Condition",validation:{required:!0},options:[{value:"good",label:"Good"},{value:"fair",label:"Fair â minor wear"},{value:"poor",label:"Poor â repair needed"}]},{key:"captureZoneAdequate",type:"select",label:"Capture Zone Adequate",validation:{required:!0},options:[{value:"yes",label:"Yes"},{value:"no",label:"No"}]},{key:"faceVelocityMeasured",type:"number",label:"Face Velocity Measured",suffix:"m/s",helpText:"Average measured face velocity across the hood opening",validation:{min:0}},{key:"faceVelocityTarget",type:"number",label:"Target Face Velocity",suffix:"m/s",helpText:"Design or HSG258 recommended minimum face velocity",validation:{min:0}},{key:"hoodNotes",type:"textarea",label:"Hood / Enclosure Notes",colSpan:2}]}]},{key:"ductwork",label:"Ductwork",title:"Ductwork Assessment",content:[{kind:"section",key:"ductworkAssessment",columns:2,fields:[{key:"ductMaterial",type:"text",label:"Duct Material",validation:{required:!0},helpText:"e.g. galvanised steel, PVC, flexible hose"},{key:"ductCondition",type:"select",label:"Condition",validation:{required:!0},options:[{value:"satisfactory",label:"Satisfactory"},{value:"deteriorated",label:"Deteriorated"},{value:"damaged",label:"Damaged"}]},{key:"jointsSealed",type:"select",label:"Joints Sealed",validation:{required:!0},options:[{value:"yes",label:"Yes â all joints sealed"},{value:"partial",label:"Partial â some leakage noted"},{value:"no",label:"No â significant air leaks"}]},{key:"accessPointsAdequate",type:"select",label:"Access Points Adequate",validation:{required:!0},options:[{value:"yes",label:"Yes"},{value:"no",label:"No"}],helpText:"Sufficient access for cleaning, inspection and testing"},{key:"damperPositionsCorrect",type:"select",label:"Damper Positions Correct",validation:{required:!0},options:[{value:"yes",label:"Yes"},{value:"no",label:"No"},{value:"na",label:"N/A â no dampers fitted"}]},{key:"ductworkNotes",type:"textarea",label:"Ductwork Notes",colSpan:2}]}]},{key:"filter",label:"Filter",title:"Air Cleaner / Filter",content:[{kind:"section",key:"filterAssessment",columns:2,fields:[{key:"filterType",type:"text",label:"Air Cleaner / Filter Type",validation:{required:!0},helpText:"e.g. bag filter, cartridge filter, HEPA, cyclone, wet scrubber"},{key:"filterCondition",type:"select",label:"Condition",validation:{required:!0},options:[{value:"good",label:"Good"},{value:"fair",label:"Fair â approaching replacement"},{value:"poor",label:"Poor â replacement required"}]},{key:"pressureDrop",type:"number",label:"Pressure Drop Across Filter",suffix:"Pa",helpText:"Static pressure differential across the filter unit",validation:{min:0}}
1,{key:"pressureDropWithinLimits",type:"select",label:"Pressure Drop Within Limits",validation:{required:!0},options:[{value:"yes",label:"Yes"},{value:"no",label:"No â exceeds manufacturer limits"}]},{key:"filterNotes",type:"textarea",label:"Filter Notes",colSpan:2}]}]},{key:"fan",label:"Fan",title:"Fan Assessment",content:[{kind:"section",key:"fanAssessment",columns:2,fields:[{key:"fanType",type:"text",label:"Fan Type",validation:{required:!0},helpText:"e.g. centrifugal, axial, mixed flow"},{key:"fanCondition",type:"select",label:"Condition",validation:{required:!0},options:[{value:"good",label:"Good"},{value:"fair",label:"Fair â monitor"},{value:"poor",label:"Poor â repair/replace needed"}]},{key:"fanRunningCurrent",type:"number",label:"Running Current",suffix:"A",helpText:"Measured motor running current",validation:{min:0}},{key:"fanRatedCurrent",type:"number",label:"Rated Current",suffix:"A",helpText:"Motor nameplate rated current",validation:{min:0}},{key:"vibrationAcceptable",type:"select",label:"Vibration Acceptable",validation:{required:!0},options:[{value:"yes",label:"Yes"},{value:"no",label:"No â excessive vibration"}]},{key:"driveBeltFitted",type:"select",label:"Drive Belt Fitted",options:[{value:"yes",label:"Yes"},{value:"no",label:"No â direct drive"}]},{key:"driveBeltCondition",type:"select",label:"Drive Belt Condition",visibleWhen:{field:"driveBeltFitted",op:"eq",value:"yes"},options:[{value:"good",label:"Good"},{value:"worn",label:"Worn â replacement due"},{value:"poor",label:"Poor â immediate replacement"}]},{key:"fanNotes",type:"textarea",label:"Fan Notes",colSpan:2}]}]},{key:"discharge",label:"Discharge",title:"Discharge Arrangement",content:[{kind:"section",key:"dischargeAssessment",columns:2,fields:[{key:"dischargeType",type:"select",label:"Discharge Type",validation:{required:!0},options:[{value:"atmosphere",label:"Discharged to Atmosphere"},{value:"recirculated",label:"Recirculated to Workplace"}]},{key:"dischargePointAdequate",type:"select",label:"Discharge Point Adequate",validation:{required:!0},options:[{value:"yes",label:"Yes â correctly positioned"},{value:"no",label:"No â re-entrainment risk"}],helpText:"Discharge must not re-enter the building or affect neighbouring premises"},{key:"dischargeNotes",type:"textarea",label:"Discharge Notes",colSpan:2}]}]},{key:"measurements",label:"Measurements",title:"Transport Velocity & Static Pressure Measurements",content:[{kind:"repeating",key:"velocityReadings",titleTemplate:"Measuring Point {index}",itemLabel:"Measuring Point",maxItems:20,minItems:1,collapsible:!0,defaultItem:{pointLocation:"",measuredVelocity:"",minimumRequiredVelocity:"",staticPressure:""},sections:[{key:"pointDetails",columns:2,fields:[{key:"pointLocation",type:"text",label:"Measuring Point Location",validation:{required:!0},placeholder:"e.g. Main branch duct, Hood 1 takeoff"},{key:"measuredVelocity",type:"number",label:"Measured Transport Velocity",suffix:"m/s",validation:{required:!0,min:0}},{key:"minimumRequiredVelocity",type:"number",label:"Minimum Required Velocity",suffix:"m/s",validation:{required:!0,min:0},helpText:"Per HSG258 Table 12 (recommended minimum duct velocities) for the contaminant being conveyed"},{key:"staticPressure",type:"number",label:"Static Pressure",suffix:"Pa",helpText:"Measured static pressure at this point"}]}]},{kind:"section",key:"additionalPressure",title:"Additional Static Pressure Readings",columns:2,fields:[{key:"spAtHood",type:"number",label:"Static Pressure at Hood",suffix:"Pa"},{key:"spBeforeFilter",type:"number",label:"Static Pressure Before Filter",suffix:"Pa"},{key:"spAfterFilter",type:"number",label:"Static Pressure After Filter",suffix:"Pa"},{key:"spAtFanInlet",type:"number",label:"Static Pressure at Fan Inlet",suffix:"Pa"},{key:"spAtFanOutlet",type:"number",label:"Static Pressure at Fan Outlet",suffix:"Pa"},{key:"spAtDischarge",type:"number",label:"Static Pressure at Discharge",suffix:"Pa"}]}]},{key:"assessment",label:"Assessment",title:"Overall Assessment & Recommendations",content:[{kind:"section",key:"overallAssessment",columns:2,fields:[{key:"systemAdequate",type:"select",label:"System Adequate to Control Exposure",validation:{required:!0},colSpan:2,options:[{value:"yes",label:"Yes â system adequately controls exposure"},{value:"no",label:"No â system does not adequately control exposure"}],helpText:"In the opinion of the competent examiner, does this LEV system adequately control employee exposure to hazardous substances?"},{key:"repairsRequired",type:"select",label:"Repairs Required",validation:{required:!0},options:[{value:"yes",label:"Yes"},{value:"no",label:"No"}]},{key:"repairDetails",type:"textarea",label:"Repair Details",colSpan:2,visibleWhen:{field:"repairsRequired",op:"eq",value:"yes"},helpText:"Describe all repairs required and recommended timescale for completion"},{key:"coshhReg9Compliant",type:"select",label:"COSHH Regulation 9 Compliant",validation:{required:!0},colSpan:2,options:[{value:"compliant",label:"Compliant â meets COSHH Regulation 9 requirements"},{value:"non_compliant",label:"Non-Compliant â does not meet COSHH Regulation 9 requirements"}]}]},{kind:"section",key:"recommendations",title:"Recommendations",columns:2,fields:[{key:"nextTestFrequency",type:"select",label:"Recommended Next Test Frequency",validation:{required:!0},options:[{value:"1",label:"1 month (COSHH Schedule 4: blasting of metal castings, jute cloth manufacture)"},{value:"6",label:"6 months (COSHH Schedule 4: metal grinding or polishing, non-ferrous metal castings)"},{value:"12",label:"12 months"},{value:"14",label:"14 months (standard maximum interval)"}
1],helpText:"Per COSHH Regulations 2002 Schedule 4 and HSG258 Table 18"},{key:"recommendationNotes",type:"textarea",label:"Recommendations / Additional Comments",colSpan:2,helpText:"Include any recommendations for improvement, maintenance requirements, or operational advice"}]}]},{key:"declaration",label:"Declaration",title:"Examiner Declaration",content:[{kind:"section",key:"declarationInfo",fields:[{key:"declarationText",type:"info",label:"",helpText:"I certify that this thorough examination and test (TExT) has been carried out in accordance with COSHH Regulations 2002, Regulation 9, and the guidance in HSG258. The results recorded above are a true and accurate record of my findings."}]},{kind:"section",key:"examinerSignatureSection",columns:2,fields:[{key:"examinerSignature",type:"signature",label:"Examiner Signature",validation:{required:!0},colSpan:2},{key:"signatureDate",type:"date",label:"Date",validation:{required:!0},defaultValue:"today"}]}]}],complianceChecklist:{title:"COSHH Regulation 9 / HSG258 Compliance Checks",items:[{label:"Examination date recorded",field:"examinationDate",expect:{op:"truthy"}},{label:"Next examination due date set",field:"nextExaminationDue",expect:{op:"truthy"}},{label:"Premises identified",field:"businessName",expect:{op:"truthy"}},{label:"LEV system reference recorded",field:"systemRef",expect:{op:"truthy"}},{label:"Process and substances controlled identified",field:"processControlled",expect:{op:"truthy"}},{label:"Hood / enclosure capture zone adequate",field:"captureZoneAdequate",expect:{op:"eq",value:"yes"},severity:"advisory"},{label:"Filter pressure drop within limits",field:"pressureDropWithinLimits",expect:{op:"eq",value:"yes"},severity:"advisory"}
1,{label:"Fan vibration acceptable",field:"vibrationAcceptable",expect:{op:"eq",value:"yes"},severity:"advisory"},{label:"System adequate to control exposure",field:"systemAdequate",expect:{op:"eq",value:"yes"},severity:"advisory"},{label:"COSHH Regulation 9 compliant",field:"coshhReg9Compliant",expect:{op:"eq",value:"compliant"},severity:"advisory"},{label:"Test instrument calibrated",field:"instrumentCalibrationDate",expect:{op:"truthy"}},{label:"Examiner qualifications recorded",field:"examinerQualifications",expect:{op:"truthy"}},{label:"Examiner has signed",field:"examinerSignature",expect:{op:"truthy"}}]},warnings:[{message:"Face velocity is below the target â hood may not adequately capture contaminants",field:"faceVelocityMeasured",compareField:"faceVelocityTarget",op:"lt"},{message:"Transport velocity is below the minimum required â risk of duct settlement",field:"measuredVelocity",compareField:"minimumRequiredVelocity",op:"lt",repeatKey:"velocityReadings"},{message:"System does NOT adequately control exposure â employees may be exposed to hazardous substances. Remedial action and re-test required.",field:"systemAdequate",op:"eq",value:"no"},{message:"LEV does not meet COSHH Regulation 9 â the responsible person must act on the identified defects.",field:"coshhReg9Compliant",op:"eq",value:"non_compliant"},{message:"Hood / enclosure capture zone is inadequate â contaminant capture may be failing.",field:"captureZoneAdequate",op:"eq",value:"no"}],review:{sections:[{title:"Certificate Details",columns:2,fields:[{key:"certRef",label:"Certificate Reference"},{key:"examinationDate",label:"Examination Date",format:"date"},{key:"nextExaminationDue",label:"Next Examination Due",format:"date"}]},{title:"Premises",columns:2,fields:[{key:"businessName",label:"Business Name"},{key:"departmentArea",label:"Department / Area"},{key:"premisesAddress",label:"Premises Address"}]},{title:"Responsible Person",columns:2,fields:[{key:"responsiblePersonName",label:"Name"},{key:"responsiblePersonPosition",label:"Position"}]},{title:"Examiner Details",columns:2,fields:[{key:"examinerName",label:"Examiner Name"},{key:"examinerCompany",label:"Company"},{key:"examinerQualifications",label:"Qualifications / Competence"},{key:"instrumentMake",label:"Test Instrument"},{key:"instrumentSerial",label:"Serial Number"},{key:"instrumentCalibrationDate",label:"Calibration Date",format:"date"}]},{title:"LEV System Details",columns:2,fields:[{key:"systemRef",label:"System Reference / ID"},{key:"systemManufacturer",label:"Manufacturer"},{key:"processControlled",label:"Process Controlled"},{key:"substancesControlled",label:"Substances Controlled"},{key:"systemType",label:"System Type",format:"enum"},{key:"systemTypeOther",label:"Other System Type"},{key:"dateInstalled",label:"Date Installed",format:"date"},{key:"numberOfHoods",label:"Number of Hoods / Capture Points"}]},{title:"Hood / Enclosure Assessment",columns:2,fields:[{key:"hoodType",label:"Hood / Enclosure Type"},{key:"hoodDimensions",label:"Dimensions (mm)"},{key:"hoodCondition",label:"Condition",format:"enum"},{key:"captureZoneAdequate",label:"Capture Zone Adequate",format:"enum"},{key:"faceVelocityMeasured",label:"Face Velocity Measured (m/s)"},{key:"faceVelocityTarget",label:"Target Face Velocity (m/s)"},{key:"hoodNotes",label:"Notes"}]},{title:"Ductwork Assessment",columns:2,fields:[{key:"ductMaterial",label:"Duct Material"},{key:"ductCondition",label:"Condition",format:"enum"},{key:"jointsSealed",label:"Joints Sealed",format:"enum"},{key:"accessPointsAdequate",label:"Access Points Adequate",format:"enum"},{key:"damperPositionsCorrect",label:"Damper Positions Correct",format:"enum"},{key:"ductworkNotes",label:"Notes"}]},{title:"Air Cleaner / Filter",columns:2,fields:[{key:"filterType",label:"Type"},{key:"filterCondition",label:"Condition",format:"enum"},{key:"pressureDrop",label:"Pressure Drop (Pa)"},{key:"pressureDropWithinLimits",label:"Within Limits",format:"enum"},{key:"filterNotes",label:"Notes"}]},{title:"Fan Assessment",columns:2,fields:[{key:"fanType",label:"Fan Type"},{key:"fanCondition",label:"Condition",format:"enum"},{key:"fanRunningCurrent",label:"Running Current (A)"},{key:"fanRatedCurrent",label:"Rated Current (A)"},{key:"vibrationAcceptable",label:"Vibration Acceptable",format:"enum"},{key:"driveBeltFitted",label:"Drive Belt Fitted",format:"enum"},{key:"driveBeltCondition",label:"Drive Belt Condition",format:"enum"},{key:"fanNotes",label:"Notes"}]},{title:"Discharge Arrangement",columns:2,fields:[{key:"dischargeType",label:"Discharge Type",format:"enum"},{key:"dischargePointAdequate",label:"Discharge Point Adequate",format:"enum"},{key:"dischargeNotes",label:"Notes"}]},{key:"velocityReadings",titleTemplate:"Measuring Point {index}
1",sections:[{title:"Transport Velocity & Static Pressure",columns:2,fields:[{key:"pointLocation",label:"Location"},{key:"measuredVelocity",label:"Measured Velocity (m/s)"},{key:"minimumRequiredVelocity",label:"Minimum Required Velocity (m/s)"},{key:"staticPressure",label:"Static Pressure (Pa)"}]}]},{title:"Additional Static Pressure Readings",columns:2,fields:[{key:"spAtHood",label:"At Hood (Pa)"},{key:"spBeforeFilter",label:"Before Filter (Pa)"},{key:"spAfterFilter",label:"After Filter (Pa)"},{key:"spAtFanInlet",label:"At Fan Inlet (Pa)"},{key:"spAtFanOutlet",label:"At Fan Outlet (Pa)"},{key:"spAtDischarge",label:"At Discharge (Pa)"}]},{title:"Overall Assessment",columns:2,fields:[{key:"systemAdequate",label:"System Adequate to Control Exposure",format:"enum"},{key:"repairsRequired",label:"Repairs Required",format:"enum"},{key:"repairDetails",label:"Repair Details"},{key:"coshhReg9Compliant",label:"COSHH Regulation 9 Compliant",format:"enum"}]},{title:"Recommendations",columns:2,fields:[{key:"nextTestFrequency",label:"Next Test Frequency (months)",format:"enum"},{key:"recommendationNotes",label:"Recommendations / Additional Comments"}]},{title:"Examiner Declaration",columns:2,fields:[{key:"examinerName",label:"Examiner Name"},{key:"examinerSignature",label:"Signature",format:"signature"},{key:"signatureDate",label:"Date",format:"date"}]}]},pdf:{title:"Local Exhaust Ventilation (LEV) Test Certificate",subtitle:"Thorough Examination & Test â COSHH Regulations 2002, Regulation 9 / HSG258",certRefField:"certRef",sections:[{kind:"cover",title:"Local Exhaust Ventilation (LEV) Test Certificate",subtitle:"Thorough Examination & Test (TExT) â COSHH Regulations 2002",fields:[{label:"Certificate Ref",key:"certRef"},{label:"Examination Date",key:"examinationDate",format:"date"},{label:"Next Examination Due",key:"nextExaminationDue",format:"date"},{label:"Business Name",key:"businessName"},{label:"Premises Address",key:"premisesAddress"},{label:"System Ref / ID",key:"systemRef"},{label:"Process Controlled",key:"processControlled"},{label:"Examiner",key:"examinerName"},{label:"Examiner Company",key:"examinerCompany"}],disclaimer:"This certificate follows COSHH Regulations 2002, Regulation 9 and the guidance in HSG258. Records must be kept for at least 5 years. It is the record of the person who signed it, who is responsible for its accuracy."},{kind:"page-break"},{kind:"table",title:"Premises Details",rows:[{label:"Business Name",key:"businessName"},{label:"Premises Address",key:"premisesAddress"},{label:"Department / Area",key:"departmentArea"},{label:"Responsible Person",key:"responsiblePersonName"},{label:"Position",key:"responsiblePersonPosition"}]},{kind:"table",title:"Examiner Details",rows:[{label:"Examiner Name",key:"examinerName"},{label:"Company",key:"examinerCompany"},{label:"Qualifications / Competence",key:"examinerQualifications"},{label:"Test Instrument",key:"instrumentMake"},{label:"Serial Number",key:"instrumentSerial"},{label:"Calibration Date",key:"instrumentCalibrationDate",format:"date"}]},{kind:"table",title:"LEV System Details",rows:[{label:"System Reference / ID",key:"systemRef"},{label:"Manufacturer",key:"systemManufacturer"},{label:"Process Controlled",key:"processControlled"},{label:"Substances Controlled",key:"substancesControlled"},{label:"System Type",key:"systemType",format:"enum"},{label:"Date Installed",key:"dateInstalled",format:"date"},{label:"Number of Hoods / Capture Points",key:"numberOfHoods"}]},{kind:"table",title:"Hood / Enclosure Assessment",rows:[{label:"Hood / Enclosure Type",key:"hoodType"},{label:"Dimensions (mm)",key:"hoodDimensions"},{label:"Condition",key:"hoodCondition",format:"enum"},{label:"Capture Zone Adequate",key:"captureZoneAdequate",format:"enum"},{label:"Face Velocity Measured (m/s)",key:"faceVelocityMeasured"},{label:"Target Face Velocity (m/s)",key:"faceVelocityTarget"},{label:"Notes",key:"hoodNotes"}]},{kind:"table",title:"Ductwork Assessment",rows:[{label:"Duct Material",key:"ductMaterial"},{label:"Condition",key:"ductCondition",format:"enum"},{label:"Joints Sealed",key:"jointsSealed",format:"enum"},{label:"Access Points Adequate",key:"accessPointsAdequate",format:"enum"}
1,{label:"Damper Positions Correct",key:"damperPositionsCorrect",format:"enum"},{label:"Notes",key:"ductworkNotes"}]},{kind:"table",title:"Air Cleaner / Filter",rows:[{label:"Type",key:"filterType"},{label:"Condition",key:"filterCondition",format:"enum"},{label:"Pressure Drop (Pa)",key:"pressureDrop"},{label:"Pressure Drop Within Limits",key:"pressureDropWithinLimits",format:"enum"},{label:"Notes",key:"filterNotes"}]},{kind:"table",title:"Fan Assessment",rows:[{label:"Fan Type",key:"fanType"},{label:"Condition",key:"fanCondition",format:"enum"},{label:"Running Current (A)",key:"fanRunningCurrent"},{label:"Rated Current (A)",key:"fanRatedCurrent"},{label:"Vibration Acceptable",key:"vibrationAcceptable",format:"enum"},{label:"Drive Belt Fitted",key:"driveBeltFitted",format:"enum"},{label:"Drive Belt Condition",key:"driveBeltCondition",format:"enum"},{label:"Notes",key:"fanNotes"}]},{kind:"table",title:"Discharge Arrangement",rows:[{label:"Discharge Type",key:"dischargeType",format:"enum"},{label:"Discharge Point Adequate",key:"dischargePointAdequate",format:"enum"},{label:"Notes",key:"dischargeNotes"}]},{kind:"page-break"},{kind:"repeating",key:"velocityReadings",title:"Transport Velocity & Static Pressure Measurements",columns:[{header:"#",key:"_index"},{header:"Location",key:"pointLocation"},{header:"Measured (m/s)",key:"measuredVelocity"},{header:"Min Req. (m/s)",key:"minimumRequiredVelocity"},{header:"Static (Pa)",key:"staticPressure"}]},{kind:"table",title:"Additional Static Pressure Readings",rows:[{label:"At Hood (Pa)",key:"spAtHood"},{label:"Before Filter (Pa)",key:"spBeforeFilter"},{label:"After Filter (Pa)",key:"spAfterFilter"},{label:"At Fan Inlet (Pa)",key:"spAtFanInlet"},{label:"At Fan Outlet (Pa)",key:"spAtFanOutlet"},{label:"At Discharge (Pa)",key:"spAtDischarge"}]},{kind:"table",title:"Overall Assessment",rows:[{label:"System Adequate to Control Exposure",key:"systemAdequate",format:"enum"},{label:"Repairs Required",key:"repairsRequired",format:"enum"},{label:"Repair Details",key:"repairDetails"},{label:"COSHH Regulation 9 Compliant",key:"coshhReg9Compliant",format:"enum"},{label:"Recommended Next Test Frequency",key:"nextTestFrequency",format:"enum"},{label:"Recommendations / Additional Comments",key:"recommendationNotes"}]},{kind:"signatures",title:"Examiner Declaration",signatures:[{label:"LEV Examiner",signatureKey:"examinerSignature",declarationKey:"declarationText",dateKey:"signatureDate",nameKey:"examinerName",additionalInfo:[{label:"Company",key:"examinerCompany"},{label:"Qualifications",key:"examinerQualifications"}]}]}]}};export{l as default};
Line numbers count LF bytes from the start of the resource, as the search results do. Vendor segments are library code the classifier recognised; they are stored but not indexed. Bytes are shown as Latin1 characters, one per byte.