PageSourceSearch

https://certbox.app/assets/gs-11-eqdpWzfr.js

js certbox.app collected 2026-10-02 00:44:34 UTC 22,465 bytes, 1 lines download raw bytes

1(function(){try{var e=typeof window<"u"?window:typeof global<"u"?global:typeof globalThis<"u"?globalThis:typeof self<"u"?self:{};e.SENTRY_RELEASE={id:"95830b11ff50f9e7292c5691d851aab9e169cfb2"};var a=new e.Error().stack;a&&(e._sentryDebugIds=e._sentryDebugIds||{},e._sentryDebugIds[a]="4a19428c-6eb3-4f3b-9970-abc527cf2525",e._sentryDebugIdIdentifier="sentry-dbid-4a19428c-6eb3-4f3b-9970-abc527cf2525")}catch{}})();const t={typeCode:"GS-11",country:"GB",title:"Non-Domestic Plant Commissioning & Servicing Record (CP15)",version:5,defaultValidityMonths:12,issueDateField:"serviceDate",propertySource:{address:"premisesAddress"},steps:[{key:"premises",label:"Premises",title:"Premises & Responsible Person",content:[{kind:"section",key:"certDetails",title:"Certificate Details",columns:2,fields:[{key:"certRef",type:"text",label:"Certificate reference",validation:{required:!0},placeholder:"e.g. CP15-2025-001"},{key:"serviceDate",type:"date",label:"Date of service / commissioning",validation:{required:!0},defaultValue:"today"},{key:"workType",type:"select",label:"Type of work",validation:{required:!0},options:[{value:"commissioning",label:"Commissioning"},{value:"service",label:"Service / maintenance"},{value:"breakdown_repair",label:"Breakdown repair"},{value:"decommissioning",label:"Decommissioning"}]}]},{kind:"section",key:"premisesDetails",title:"Premises Details",columns:2,fields:[{key:"businessName",prefillFrom:"companyName",type:"text",label:"Business / site name",validation:{required:!0}},{key:"premisesAddress",type:"textarea",label:"Premises address",validation:{required:!0},colSpan:2},{key:"premisesType",type:"select",label:"Premises type",validation:{required:!0},options:[{value:"commercial",label:"Commercial office / retail"},{value:"industrial",label:"Industrial / warehouse"},{value:"educational",label:"School / college / university"},{value:"healthcare",label:"Hospital / care home"},{value:"leisure",label:"Leisure / sports centre"},{value:"public",label:"Public building / community"},{value:"residential_communal",label:"Communal residential (plant room)"},{value:"other",label:"Other"}]},{key:"premisesTypeOther",type:"text",label:"Other premises type",visibleWhen:{field:"premisesType",op:"eq",value:"other"}}]},{kind:"section",key:"responsiblePerson",title:"Responsible Person",columns:2,fields:[{key:"responsiblePersonName",type:"text",label:"Name",validation:{required:!0}},{key:"responsiblePersonPosition",type:"text",label:"Position",placeholder:"e.g. Facilities Manager, Building Manager"},{key:"responsiblePersonContact",type:"text",label:"Contact number"},{key:"responsiblePersonEmail",type:"text",label:"Email address"}]}]},{key:"engineer",label:"Engineer",title:"Engineer Details",content:[{kind:"section",key:"engineerDetails",title:"Engineer",columns:2,fields:[{key:"engineerName",type:"text",label:"Engineer name",validation:{required:!0}},{key:"gasSafeRegNumber",prefillFrom:"gasSafeRegNumber",type:"text",label:"Gas Safe registration number",validation:{required:!0},helpText:"Your business registration number on the Gas Safe Register"},{key:"gasSafeIdNumber",prefillFrom:"engineerId",type:"text",label:"Gas Safe ID number",validation:{required:!0},helpText:"The unique number on the front of your Gas Safe ID card"},{key:"commercialQualifications",type:"text",label:"Non-domestic qualifications held",validation:{required:!0},helpText:"e.g. COCN1, CODNCO1, CDGA1, TPCP1"}]},{kind:"section",key:"companyDetails",title:"Company",columns:2,fields:[{key:"companyName",prefillFrom:"companyName",type:"text",label:"Company name"},{key:"companyAddress",prefillFrom:"companyAddress",type:"textarea",label:"Company address",colSpan:2},{key:"companyContact",prefillFrom:"companyPhone",type:"text",label:"Company contact"}]}]},{key:"gasSupply",label:"Gas Supply",title:"Gas Supply Details",content:[{kind:"section",key:"gasSupplyDetails",title:"Gas Supply",columns:2,fields:[{key:"meterLocation",type:"text",label:"Meter location",validation:{required:!0}},{key:"meterNumber",type:"text",label:"Meter number / serial"},{key:"ecvLocation",type:"text",label:"Emergency control valve (ECV) location",validation:{required:!0}},{key:"fuelType",type:"select",label:"Fuel type",validation:{required:!0},options:[{value:"natural_gas",label:"Natural gas"},{value:"lpg_bulk",label:"LPG (bulk tank)"},{value:"lpg_cylinder",label:"LPG (cylinder)"}]},{key:"supplyPressure",type:"number",label:"Supply pressure",suffix:"mbar",helpText:"Measured at meter outlet"},{key:"governorLocation",type:"text",label:"Governor location (if applicable)"},{key:"governorSetPressure",type:"number",label:"Governor set pressure",suffix:"mbar"}]},{kind:"section",key:"gasTightness",title:"Gas Tightness Test",columns:2,fields:[{key:"tightnessTestCarriedOut",type:"radio-group",label:"Tightness test carried out",validation:{required:!0},options:[{value:"yes",label:"Yes"},{value:"no",label:"No — see CP16"}]},{key:"tightnessTestResult",type:"radio-group",label:"Tightness test result",visibleWhen:{field:"tightnessTestCarriedOut",op:"eq",value:"yes"},options:[{value:"pass",label:"Pass"},{value:"fail",label:"Fail"}]},{key:"tightnessTestNotes",type:"textarea",label:"Tightness test notes",colSpan:2}]}]}
1,{key:"appliances",label:"Appliances",title:"Appliance Details",content:[{kind:"section",key:"applianceInfo",fields:[{key:"info_appliances",type:"info",label:"Record details for each non-domestic gas appliance commissioned, serviced, or inspected. This includes commercial boilers, warm air heaters, radiant tube heaters, cabinet heaters, overhead radiant heaters, and all other non-domestic gas-fired plant."}]},{kind:"repeating",key:"appliances",titleTemplate:"Appliance {index}: {applianceType} — {make} {model}",itemLabel:"Appliance",maxItems:20,minItems:1,collapsible:!0,defaultItem:{applianceType:"",make:"",model:"",serialNumber:"",location:"",gcNumber:"",yearInstalled:"",gasRateKw:"",burnerPressureMbar:"",co:"",coCo2Ratio:"",co2Reading:"",flueTempC:"",flueType:"",flueFlowTest:"",spillageTest:"",ventilationAdequate:"",safetyDevicesOperational:"",safetyDeviceNotes:"",condition:"",safeToUse:"",unsafeClassification:"",warningLabelAttached:"",workCarriedOut:"",applianceNotes:""},sections:[{key:"applianceIdentification",title:"Identification",columns:2,fields:[{key:"applianceType",type:"select",label:"Appliance type",validation:{required:!0},options:[{value:"boiler_atmospheric",label:"Boiler — atmospheric"},{value:"boiler_fan_assisted",label:"Boiler — fan assisted"},{value:"boiler_condensing",label:"Boiler — condensing"},{value:"boiler_modular",label:"Boiler — modular / cascade"},{value:"warm_air_heater",label:"Warm air heater (direct / indirect)"},{value:"radiant_tube",label:"Radiant tube heater"},{value:"radiant_plaque",label:"Radiant plaque heater"},{value:"cabinet_heater",label:"Cabinet heater"},{value:"overhead_radiant",label:"Overhead luminous radiant heater"},{value:"air_handling_unit",label:"Air handling unit (gas-fired)"},{value:"water_heater",label:"Water heater (commercial)"},{value:"steam_generator",label:"Steam generator / boiler"},{value:"destratification_fan",label:"Destratification fan (gas)"},{value:"other",label:"Other"}]},{key:"make",type:"text",label:"Make / manufacturer",validation:{required:!0}},{key:"model",type:"text",label:"Model",validation:{required:!0}},{key:"serialNumber",type:"text",label:"Serial number"},{key:"location",type:"text",label:"Location within premises",validation:{required:!0}},{key:"gcNumber",type:"text",label:"GC number (if available)",helpText:"Gas Council approval number from appliance data plate"},{key:"yearInstalled",type:"text",label:"Year of installation (approx.)"}]},{key:"applianceCombustion",title:"Combustion & Flue",columns:2,fields:[{key:"gasRateKw",type:"number",label:"Gas rate (measured)",suffix:"kW"},{key:"burnerPressureMbar",type:"number",label:"Burner pressure",suffix:"mbar"},{key:"co",type:"number",label:"CO reading (ambient / air-free)",suffix:"ppm"},{key:"coCo2Ratio",type:"number",label:"CO/CO2 ratio"},{key:"co2Reading",type:"number",label:"CO2 reading",suffix:"%"},{key:"flueTempC",type:"number",label:"Flue temperature",suffix:"°C"},{key:"flueType",type:"select",label:"Flue type",options:[{value:"open_flue",label:"Open flue (natural draught)"},{value:"room_sealed",label:"Room sealed (balanced flue)"},{value:"fan_flue",label:"Fan-assisted flue"},{value:"se_duct",label:"SE duct"},{value:"u_duct",label:"U duct"},{value:"flueless",label:"Flueless"},{value:"shared_flue",label:"Shared / common flue"}]},{key:"flueFlowTest",type:"radio-group",label:"Flue flow / draught test",options:[{value:"pass",label:"Pass"},{value:"fail",label:"Fail"},{value:"na",label:"N/A (room sealed)"}]},{key:"spillageTest",type:"radio-group",label:"Spillage test",options:[{value:"pass",label:"Pass"},{value:"fail",label:"Fail"},{value:"na",label:"N/A (room sealed)"}]}]},{key:"applianceSafety",title:"Safety & Ventilation",columns:2,fields:[{key:"ventilationAdequate",type:"radio-group",label:"Ventilation adequate",validation:{required:!0},options:[{value:"yes",label:"Yes"},{value:"no",label:"No"},{value:"na",label:"N/A (room sealed)"}]},{key:"safetyDevicesOperational",type:"radio-group",label:"Safety devices operational",validation:{required:!0},helpText:"Flame failure, overheat stat, pressure relief, gas valve, etc.",options:[{value:"yes",label:"Yes — all operational"},{value:"no",label:"No — defect noted"}]},{key:"safetyDeviceNotes",type:"textarea",label:"Safety device details / defects",colSpan:2}]},{key:"applianceCondition",title:"Condition & Outcome",columns:2,fields:[{key:"condition",type:"radio-group",label:"Condition",validation:{required:!0},options:[{value:"satisfactory",label:"Satisfactory"},{value:"attention_required",label:"Attention required"},{value:"unsafe",label:"Unsafe"}]},{key:"safeToUse",type:"radio-group",label:"Safe to use",validation:{required:!0},options:[{value:"yes",label:"Yes"},{value:"no",label:"No"}]},{key:"unsafeClassification",type:"select",label:"Unsafe classification (GIUSP)",validation:{required:!0},visibleWhen:{field:"safeToUse",op:"eq",value:"no"},options:[{value:"id",label:"Immediately Dangerous (ID)"},{value:"ar",label:"At Risk (AR)"}]},{key:"warningLabelAttached",type:"radio-group",label:"Warning label / notice attached",visibleWhen:{field:"safeToUse",op:"eq",value:"no"},options:[{value:"yes",label:"Yes"},{value:"no",label:"No"}]},{key:"workCarriedOut",type:"textarea",label:"Work carried out",colSpan:2,helpText:"Describe commissioning checks, servicing tasks, or repairs completed"},{key:"applianceNotes",type:"textarea",label:"Notes / defects / re
1commendations",colSpan:2}]}]}]},{key:"outcome",label:"Outcome",title:"Overall Outcome & Recommendations",content:[{kind:"section",key:"overallOutcome",title:"Overall Outcome",columns:2,fields:[{key:"overallResult",type:"radio-group",label:"Overall result",validation:{required:!0},options:[{value:"pass",label:"Pass — all appliances safe to use"},{value:"fail",label:"Fail — action required"}]}]},{kind:"section",key:"defectsRecommendations",title:"Defects & Recommendations",fields:[{key:"defectsFound",type:"textarea",label:"Defects found",helpText:"List all defects observed during commissioning / servicing"},{key:"recommendations",type:"textarea",label:"Recommendations",helpText:"Include remedial works, parts required, or follow-up actions"},{key:"partsUsed",type:"textarea",label:"Parts used / replaced"},{key:"nextServiceDate",type:"date",label:"Next service due",helpText:"Recommended within 12 months",defaultValue:"expiry"}]}]},{key:"declaration",label:"Declaration",title:"Declaration & Signatures",content:[{kind:"section",key:"declarationInfo",title:"Declaration",fields:[{key:"info_declaration",type:"info",label:"I certify that the non-domestic gas appliance(s) detailed above have been commissioned / serviced / inspected in accordance with the Gas Safety (Installation and Use) Regulations 1998, the manufacturer’s instructions, and relevant IGEM standards. All appliances have been checked for safe operation, combustion performance, flue integrity, and ventilation adequacy.",colSpan:2}]},{kind:"section",key:"engineerSignatureSection",title:"Engineer Signature",fields:[{key:"engineerSignature",type:"signature",label:"Engineer signature",validation:{required:!0}},{key:"signatureDate",type:"date",label:"Date",validation:{required:!0},defaultValue:"today"}]},{kind:"section",key:"responsiblePersonSignatureSection",title:"Responsible Person Signature",fields:[{key:"responsiblePersonSignature",type:"signature",label:"Responsible person signature"},{key:"responsiblePersonSignatureDate",type:"date",label:"Date"}]}]}],complianceChecklist:{title:"CP15 Non-Domestic Plant Compliance Checks",items:[{label:"Certificate reference provided",field:"certRef",expect:{op:"truthy"}},{label:"Service / commissioning date recorded",field:"serviceDate",expect:{op:"truthy"}},{label:"Type of work recorded",field:"workType",expect:{op:"truthy"}},{label:"Business name recorded",field:"businessName",expect:{op:"truthy"}},{label:"Premises address recorded",field:"premisesAddress",expect:{op:"truthy"}},{label:"Responsible person identified",field:"responsiblePersonName",expect:{op:"truthy"}},{label:"Engineer name recorded",field:"engineerName",expect:{op:"truthy"}},{label:"Gas Safe registration number recorded",field:"gasSafeRegNumber",expect:{op:"truthy"}},{label:"Gas Safe ID number recorded",field:"gasSafeIdNumber",expect:{op:"truthy"}},{label:"Non-domestic qualifications recorded",field:"commercialQualifications",expect:{op:"truthy"}},{label:"Gas tightness test status recorded",field:"tightnessTestCarriedOut",expect:{op:"truthy"}},{label:"Overall result determined",field:"overallResult",expect:{op:"truthy"}},{label:"Engineer has signed",field:"engineerSignature",expect:{op:"truthy"}},{label:"Signature date recorded",field:"signatureDate",expect:{op:"truthy"}}]},warnings:[{message:"Appliance marked as unsafe — ensure warning label / notice is attached, responsible person is notified, and CP14 Warning / Advice Notice is issued.",field:"safeToUse",repeatKey:"appliances",op:"eq",value:"no"}],review:{sections:[{title:"Certificate Details",columns:2,fields:[{key:"certRef",label:"Certificate reference"},{key:"serviceDate",label:"Date of service / commissioning",format:"date"},{key:"workType",label:"Type of work",format:"enum"}]},{title:"Premises",columns:2,fields:[{key:"businessName",label:"Business / site name"},{key:"premisesAddress",label:"Premises address"},{key:"premisesType",label:"Premises type",format:"enum"}]},{title:"Responsible Person",columns:2,fields:[{key:"responsiblePersonName",label:"Name"},{key:"responsiblePersonPosition",label:"Position"},{key:"responsiblePersonContact",label:"Contact"}]},{title:"Engineer",columns:2,fields:[{key:"engineerName",label:"Engineer name"},{key:"gasSafeRegNumber",label:"Gas Safe reg. number"},{key:"gasSafeIdNumber",label:"Gas Safe ID number"},{key:"commercialQualifications",label:"Non-domestic qualifications"},{key:"companyName",label:"Company"},{key:"companyAddress",label:"Company address"},{key:"companyContact",label:"Company contact"}]},{title:"Gas Supply",columns:2,fields:[{key:"meterLocation",label:"Meter location"},{key:"meterNumber",label:"Meter number"},{key:"ecvLocation",label:"ECV location"},{key:"fuelType",label:"Fuel type",format:"enum"},{key:"supplyPressure",label:"Supply pressure (mbar)"},{key:"governorLocation",label:"Governor location"},{key:"governorSetPressure",label:"Governor set pressure (mbar)"}]},{title:"Gas Tightness Test",columns:2,fields:[{key:"tightnessTestCarriedOut",label:"Test carried out",format:"enum"},{key:"tightnessTestResult",label:"Result",format:"enum"},{key:"tightnessTestNotes",label:"Notes"}]}
1,{key:"appliances",titleTemplate:"Appliance: {applianceType} — {make} {model}",sections:[{title:"Appliance",columns:2,fields:[{key:"warningLabelAttached",label:"Warning label / notice attached",format:"enum"},{key:"applianceType",label:"Type",format:"enum"},{key:"make",label:"Make"},{key:"model",label:"Model"},{key:"serialNumber",label:"Serial number"},{key:"location",label:"Location"},{key:"gcNumber",label:"GC number"},{key:"yearInstalled",label:"Year installed"},{key:"gasRateKw",label:"Gas rate (kW)"},{key:"burnerPressureMbar",label:"Burner pressure (mbar)"},{key:"co",label:"CO reading (ppm)"},{key:"coCo2Ratio",label:"CO/CO2 ratio"},{key:"co2Reading",label:"CO2 (%)"},{key:"flueTempC",label:"Flue temp (°C)"},{key:"flueType",label:"Flue type",format:"enum"},{key:"flueFlowTest",label:"Flue flow test",format:"enum"},{key:"spillageTest",label:"Spillage test",format:"enum"},{key:"ventilationAdequate",label:"Ventilation adequate",format:"enum"},{key:"safetyDevicesOperational",label:"Safety devices",format:"enum"},{key:"safetyDeviceNotes",label:"Safety device notes"},{key:"condition",label:"Condition",format:"enum"},{key:"safeToUse",label:"Safe to use",format:"enum"},{key:"unsafeClassification",label:"Unsafe classification",format:"enum"},{key:"workCarriedOut",label:"Work carried out"},{key:"applianceNotes",label:"Notes"}]}]},{title:"Overall Outcome",columns:2,fields:[{key:"overallResult",label:"Overall result",format:"enum"}]},{title:"Defects & Recommendations",fields:[{key:"defectsFound",label:"Defects found"},{key:"recommendations",label:"Recommendations"},{key:"partsUsed",label:"Parts used / replaced"},{key:"nextServiceDate",label:"Next service due",format:"date"}]},{title:"Signatures",columns:2,fields:[{key:"engineerSignature",label:"Engineer signature",format:"signature"},{key:"signatureDate",label:"Date signed",format:"date"},{key:"responsiblePersonSignature",label:"Responsible person signature",format:"signature"},{key:"responsiblePersonSignatureDate",label:"Responsible person date",format:"date"}]}]},pdf:{title:"Non-Domestic Plant Commissioning & Servicing Record (CP15)",subtitle:"GSIUR 1998 — Gas Safe Non-Domestic",certRefField:"certRef",sections:[{kind:"cover",title:"Non-Domestic Plant Commissioning & Servicing Record",subtitle:"CP15",fields:[{label:"Certificate Ref",key:"certRef"},{label:"Date",key:"serviceDate",format:"date"},{label:"Type of Work",key:"workType",format:"enum"},{label:"Business / Site",key:"businessName"},{label:"Premises Address",key:"premisesAddress"},{label:"Premises Type",key:"premisesType",format:"enum"},{label:"Responsible Person",key:"responsiblePersonName"},{label:"Engineer",key:"engineerName"},{label:"Gas Safe Reg No.",key:"gasSafeRegNumber"},{label:"Qualifications",key:"commercialQualifications"},{label:"Overall Result",key:"overallResult",format:"enum"}],disclaimer:"This record follows the Gas Safety (Installation and Use) Regulations 1998 and relevant IGEM standards for non-domestic gas installations. Only a Gas Safe registered engineer holding the correct ACS qualifications may carry out work on a gas installation. The engineer named in the declaration is responsible for the accuracy of this record and for holding the registration number shown on it."},{kind:"page-break"},{kind:"table",title:"Certificate Details",rows:[{label:"Certificate reference",key:"certRef"},{label:"Date of service / commissioning",key:"serviceDate",format:"date"},{label:"Type of work",key:"workType",format:"enum"}]},{kind:"table",title:"Premises Details",rows:[{label:"Business / site name",key:"businessName"},{label:"Premises address",key:"premisesAddress"},{label:"Premises type",key:"premisesType",format:"enum"}]},{kind:"table",title:"Responsible Person",rows:[{label:"Name",key:"responsiblePersonName"},{label:"Position",key:"responsiblePersonPosition"},{label:"Contact",key:"responsiblePersonContact"},{label:"Email",key:"responsiblePersonEmail"}]},{kind:"table",title:"Engineer Details",rows:[{label:"Engineer name",key:"engineerName"},{label:"Gas Safe registration number",key:"gasSafeRegNumber"},{label:"Gas Safe ID number",key:"gasSafeIdNumber"},{label:"Non-domestic qualifications",key:"commercialQualifications"},{label:"Company",key:"companyName"},{label:"Company address",key:"companyAddress"},{label:"Company contact",key:"companyContact"}]},{kind:"table",title:"Gas Supply",rows:[{label:"Meter location",key:"meterLocation"},{label:"Meter number",key:"meterNumber"},{label:"ECV location",key:"ecvLocation"},{label:"Fuel type",key:"fuelType",format:"enum"},{label:"Supply pressure (mbar)",key:"supplyPressure"},{label:"Governor location",key:"governorLocation"},{label:"Governor set pressure (mbar)",key:"governorSetPressure"}]},{kind:"table",title:"Gas Tightness Test",rows:[{label:"Test carried out",key:"tightnessTestCarriedOut",format:"enum"},{label:"Result",key:"tightnessTestResult",format:"enum"},{label:"Notes",key:"tightnessTestNotes"}]},{kind:"page-break"}
1,{kind:"repeating",key:"appliances",title:"Appliances Commissioned / Serviced",columns:[{header:"Location",key:"location"},{header:"Type",key:"applianceType",format:"enum"},{header:"Make",key:"make"},{header:"Model",key:"model"},{header:"Serial",key:"serialNumber"},{header:"kW",key:"gasRateKw"},{header:"CO (ppm)",key:"co"},{header:"CO/CO2",key:"coCo2Ratio"},{header:"Flue",key:"flueFlowTest",format:"enum"},{header:"Vent",key:"ventilationAdequate",format:"enum"},{header:"Devices",key:"safetyDevicesOperational",format:"enum"},{header:"Condition",key:"condition",format:"enum"},{header:"Safe",key:"safeToUse",format:"enum"},{header:"Class",key:"unsafeClassification",format:"enum"}]},{kind:"page-break"},{kind:"table",title:"Overall Outcome",rows:[{label:"Overall result",key:"overallResult",format:"enum"}]},{kind:"table",title:"Defects & Recommendations",rows:[{label:"Defects found",key:"defectsFound"},{label:"Recommendations",key:"recommendations"},{label:"Parts used / replaced",key:"partsUsed"},{label:"Next service due",key:"nextServiceDate",format:"date"}]},{kind:"signatures",title:"Declaration & Signatures",signatures:[{label:"Engineer (Non-Domestic)",signatureKey:"engineerSignature",declarationKey:"info_declaration",dateKey:"signatureDate",nameKey:"engineerName",additionalInfo:[{label:"Gas Safe Reg No.",key:"gasSafeRegNumber"},{label:"Gas Safe ID No.",key:"gasSafeIdNumber"},{label:"Qualifications",key:"commercialQualifications"},{label:"Company",key:"companyName"}]},{label:"Responsible Person",signatureKey:"responsiblePersonSignature",dateKey:"responsiblePersonSignatureDate",nameKey:"responsiblePersonName",additionalInfo:[{label:"Position",key:"responsiblePersonPosition"}]}]}]}};export{t as default};

Line numbers count LF bytes from the start of the resource, as the search results do. Vendor segments are library code the classifier recognised; they are stored but not indexed. Bytes are shown as Latin1 characters, one per byte.